The Langmuir technique has been applied to the study of natural tears and the results obtained from surface pressure-area isotherms have been correlated with those of clinical tests (the Schirmer and the TFBUT tests). The population studied only included people aged over 45. Natural tears were collected from Schirmer strips, which were placed in contact with the water subphase of a Langmuir trough for recording the surface pressure-area isotherms. These isotherms have been classified as good or weak according to the characteristics obtained. From the isotherms, characteristic values such as πlimit, CS-1max and πmax were also obtained. The analysis from the Chi-squared test indicates dependence between the Schirmer test and the type of isotherms (P<0.05). In the case of the TFBUT test and the type of isotherms the value of P>0.05 indicates that the independence cannot be discarded with the significance criteria imposed. Working with the same criteria of significance, we obtain moderate or good Pearson correlation coefficients with statistical significance (P<0.05) between the values of the Schirmer test and the πlimit, CS-1max and πmax values. On the other hand, we obtain low Pearson correlation coefficients with no statistical significance (P>0.05) between the values of the TFBUT test and the πlimit, CS-1max and πmax values.
Published in | International Journal of Ophthalmology & Visual Science (Volume 2, Issue 1) |
DOI | 10.11648/j.ijovs.20170201.13 |
Page(s) | 5-14 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2017. Published by Science Publishing Group |
Natural Tears, Surface Pressure-Area Isotherm, Elastic Modulus, Schirmer Test, Tear Film Break-Up-Time (TFBUT)
[1] | P. Kulosevi, J. Telenius, A. Koivuniemi, G. Brezesinski, A. Rantamäki, T. Viitala, E. Puukilainen, M. Ritala, S. K. Wiedmer, I. Vattulainen, J. M. Holopainen, Biophys. J. 99 (2010) 2559-2567. |
[2] | T. Kaercher, D. Hönig, D. Möbius, Internat. Ophthalmol. 17 (1993) 341-348. |
[3] | T. Kaercher, D. Hönig, D. Möbius, Orbit 14 (1995) 17-24. |
[4] | S. Hagedorn, E. Drolle, H. Lorentz, S. Srinivasan, Z. Leonenko, L. Jones, J. Optom. 8 (2015) 187-199. |
[5] | P. G. Petrov, J. M. Thompson, I. B. Abdul Rahman, R. E. Ellis, E. M. Green, F. Miano, C. P. Winlove, Exp. Eye Res. 84 (2007) 1140-1146. |
[6] | P. Mudgil, T. J. Millar, Invest. Ophthalmol. Vis. Sci. 52 (2011) 1661–1670. |
[7] | P. Mudgil, M. Torres, T. J. Millar, Colloids Surf. B 48 (2006) 128-137. |
[8] | F. Miano, M. Calcara, T. J. Millar, V. Enea, Colloids Surf. B 44 (2005) 49-55. |
[9] | T. F. Svitova, M. C. Lin, Adv. Colloid Interf. Sci. 233 (2016) 4-24. |
[10] | T. J. Millar, P. Mudgil, I. A. Butovich, C. K. Palaniappan, Invest. Ophthalmol. Vis. Sci. 50 (2009) 140-151. |
[11] | J. Torrent-Burgués, Colloids Surf. B 140 (2016) 185-188. |
[12] | M. Saad-Bhamla, C. Chai, N. I. Rabiah, J. M. Frostad, G. G. Fuller, Invest. Ophthalmol. Vis. Sci. 57 (2016) 949-958. |
[13] | B. Milder, The lacrimal apparatus. In Adler’s Physiology of the Eye, 8th Ed., R. A. Moses, W. M. Hart Eds, 1987, St Louis, Mosby, pp. 15-35. |
[14] | D. R. Korb, The tear film: structure, function and clinical examination, Butterworth Heineman, 2002. |
[15] | A. J. Bron, J. M. Tiffany, S. M. Gouveia, N. Yokoi, L. W. Voon, Exp. Eye Res. 78 (2004) 347–360. |
[16] | DEWS, Report of the Dry Eye Workshop, Ocul. Surf. 5 (2007) 75-92 and 93-107. |
[17] | P. Cho, M. Yap, Optom. Vis. Sci. 70 (1993) 152-156. |
[18] | M. A. Lemp, Int. Ophthalmol. Clin. 13 (1973) 97-102. |
[19] | A. Behrens, J. J. Doyle, R. S. Chuck, Cornea 25 (2006) 900-907. |
[20] | G. Savini, P. Prabhawasat, T. Kojima, M. Grueterich, E. Espana, E. Goto, Clinical Ophthalmology 2 (2008) 31-55. |
[21] | T. A. Saleh, B. McDermott, A. K. Bates, P. Ewings, Eye 20 (2006) 913-915. |
[22] | J. Torrent-Burgués, BioNanoSci. 1 (2011) 202-209. |
[23] | J. T. Davies, E. K. Rideal, Interfacial Phenomena, Academic Press, N. Y. 1993. |
[24] | P. Vitovic, D. P. Nikolelis, T. Hianik, Biochim. Biophys. Acta 1758 (2006) 1852-1861. |
APA Style
Ester Guaus, Carla Fàbregas, Miriam Pérez, Juan Torrent-Burgués. (2017). A Combined Clinical and Langmuir Film Study of Natural Tear Films. International Journal of Ophthalmology & Visual Science, 2(1), 5-14. https://doi.org/10.11648/j.ijovs.20170201.13
ACS Style
Ester Guaus; Carla Fàbregas; Miriam Pérez; Juan Torrent-Burgués. A Combined Clinical and Langmuir Film Study of Natural Tear Films. Int. J. Ophthalmol. Vis. Sci. 2017, 2(1), 5-14. doi: 10.11648/j.ijovs.20170201.13
@article{10.11648/j.ijovs.20170201.13, author = {Ester Guaus and Carla Fàbregas and Miriam Pérez and Juan Torrent-Burgués}, title = {A Combined Clinical and Langmuir Film Study of Natural Tear Films}, journal = {International Journal of Ophthalmology & Visual Science}, volume = {2}, number = {1}, pages = {5-14}, doi = {10.11648/j.ijovs.20170201.13}, url = {https://doi.org/10.11648/j.ijovs.20170201.13}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijovs.20170201.13}, abstract = {The Langmuir technique has been applied to the study of natural tears and the results obtained from surface pressure-area isotherms have been correlated with those of clinical tests (the Schirmer and the TFBUT tests). The population studied only included people aged over 45. Natural tears were collected from Schirmer strips, which were placed in contact with the water subphase of a Langmuir trough for recording the surface pressure-area isotherms. These isotherms have been classified as good or weak according to the characteristics obtained. From the isotherms, characteristic values such as πlimit, CS-1max and πmax were also obtained. The analysis from the Chi-squared test indicates dependence between the Schirmer test and the type of isotherms (P<0.05). In the case of the TFBUT test and the type of isotherms the value of P>0.05 indicates that the independence cannot be discarded with the significance criteria imposed. Working with the same criteria of significance, we obtain moderate or good Pearson correlation coefficients with statistical significance (P<0.05) between the values of the Schirmer test and the πlimit, CS-1max and πmax values. On the other hand, we obtain low Pearson correlation coefficients with no statistical significance (P>0.05) between the values of the TFBUT test and the πlimit, CS-1max and πmax values.}, year = {2017} }
TY - JOUR T1 - A Combined Clinical and Langmuir Film Study of Natural Tear Films AU - Ester Guaus AU - Carla Fàbregas AU - Miriam Pérez AU - Juan Torrent-Burgués Y1 - 2017/03/09 PY - 2017 N1 - https://doi.org/10.11648/j.ijovs.20170201.13 DO - 10.11648/j.ijovs.20170201.13 T2 - International Journal of Ophthalmology & Visual Science JF - International Journal of Ophthalmology & Visual Science JO - International Journal of Ophthalmology & Visual Science SP - 5 EP - 14 PB - Science Publishing Group SN - 2637-3858 UR - https://doi.org/10.11648/j.ijovs.20170201.13 AB - The Langmuir technique has been applied to the study of natural tears and the results obtained from surface pressure-area isotherms have been correlated with those of clinical tests (the Schirmer and the TFBUT tests). The population studied only included people aged over 45. Natural tears were collected from Schirmer strips, which were placed in contact with the water subphase of a Langmuir trough for recording the surface pressure-area isotherms. These isotherms have been classified as good or weak according to the characteristics obtained. From the isotherms, characteristic values such as πlimit, CS-1max and πmax were also obtained. The analysis from the Chi-squared test indicates dependence between the Schirmer test and the type of isotherms (P<0.05). In the case of the TFBUT test and the type of isotherms the value of P>0.05 indicates that the independence cannot be discarded with the significance criteria imposed. Working with the same criteria of significance, we obtain moderate or good Pearson correlation coefficients with statistical significance (P<0.05) between the values of the Schirmer test and the πlimit, CS-1max and πmax values. On the other hand, we obtain low Pearson correlation coefficients with no statistical significance (P>0.05) between the values of the TFBUT test and the πlimit, CS-1max and πmax values. VL - 2 IS - 1 ER -