Abstract: In order to understand the suitability of groundwater for drinking and irrigation purposes in Akoko northwest and Akoko northeast, water quality index calculation, % Na, Sodium Absorption Ratio (SAR), Residual Sodium Carbonate (RSC), Permeability Index (PI) and Electrical Conductivity were determined from thirteen water samples. The sequence of the abundance of the major ions is in the following order of K+ > Na+ > Ca2+ > Mg2+ for cations and Cl- > HCO3- > SO4- > F- in anions. The water quality index (WQI) obtained for the water samples ranges between 22.7 and 88.6. The water quality index classified the water into “excellent” and “good” drinking water and account for about 85% and 15% of the study area respectively. The % Na of the samples varies between 49 and 79%. Sodium Absorption Ratio (SAR) of the studied water samples varies from 1.40 to 3.56 with a mean of 2.44. The values are within 0 - 10 specified as excellent water for irrigation purpose. The Residual Sodium Carbonate (RSC) values ranges between – 51.6 and + 10.57, with an average of -14.5, which agrees with less than 2.5 specified for the purpose of irrigation. The permeability index (PI) of the water varies from 2.27 to 19.9, with an average of 7.93. The values fall within the Third category of 0 – 25 irrigation water which is rated as poor. The electrical conductivity of the water ranges from 117 to 789 μs/cm with an average of 378 μs/cm which corresponds to moderate (medium salinity). Also, the water in the study area shows variation of low salinity to high salinity. The Wilcox plot showed that the water samples have excellent – good irrigation potential except a sample taken from Arigidi Akoko which fall within “good to permissible limit.” Therefore combine all these results the water are moderately suitable for irrigation purpose and good for drinking.Abstract: In order to understand the suitability of groundwater for drinking and irrigation purposes in Akoko northwest and Akoko northeast, water quality index calculation, % Na, Sodium Absorption Ratio (SAR), Residual Sodium Carbonate (RSC), Permeability Index (PI) and Electrical Conductivity were determined from thirteen water samples. The sequence of the...Show More
Abstract: Solute contents in the vadose zone of limestone strata on Miyako Island of the Ryukyu Archipelago in Japan were measured by means of electrical conductivities (EC) of the extracted solutions of limestone core samples. A vertically nonuniform distribution of solute content was observed, which should lead to temporal variations of solute concentration in the groundwater under the water table. On the other hand, the data of chloride concentration in groundwater from 13 wells on the island was analyzed to see their long time variations. Both of these two approaches resulted in recharge rates of around 10-7 m s-1 for the vadose zone in the limestone strata of this typical uplifted carbonate island of the western Pacific Ocean.Abstract: Solute contents in the vadose zone of limestone strata on Miyako Island of the Ryukyu Archipelago in Japan were measured by means of electrical conductivities (EC) of the extracted solutions of limestone core samples. A vertically nonuniform distribution of solute content was observed, which should lead to temporal variations of solute concentratio...Show More