Due to the aftermath of COVID-19, we are using a continuous sterilization response system, such as sterilizing the interior of the building or using sterilized air in the air conditioning system. Chemical spraying is cumbersome and requires a lot of labor, and air conditioning systems have good air cleaning functions, but sterilization functions are difficult because they require sufficient residence time. Therefore, we developed an eco-friendly sterilization system that can disinfect the entire building with a single switch by adding a sterilization function to the existing lighting. It is a concept that sterilizes the space sufficiently by combining UVC-LED with high sterilization power with the existing LED surface lighting, using lighting during the day and sterilizing light inside the building without people at night. A PIR sensor was attached to each entrance or light to stop disinfection with a human body sensor in case people enter even at night. For the sterilization performance test, it was confirmed that 99.99% of 5 types of bacteria were sterilized as a result of testing the sterilization performance of attached bacteria at the maximum height of 1.5m or less of the certification body. The radiation intensity was simulated with a value similar to the dose irradiated in the experiment to have sterilizing power at the lighting height of 2.6m in an actual general office. As a result of calculating the sterilization time of the indoor space by coding the UVC-Led specification and the office space with MATLAB as input conditions, sterilization is possible if it is more than 4 hours. Through this study, an eco-friendly smart disinfection system was developed that disinfects the entire building with one switch when UVC is combined with general lighting and controlled from the central control room.
Published in | American Journal of Environmental Science and Engineering (Volume 7, Issue 3) |
DOI | 10.11648/j.ajese.20230703.12 |
Page(s) | 61-66 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2023. Published by Science Publishing Group |
Pandemic, Antibiotic Building, UVC-LEDs, Sterilization, Radiation, Simulation
[1] | Y. R., Yoon, H. J. Moon, “A study on the status of mould growth problems in residential buildings based on questionnaire survey”, Journal of Odor and indoor Environment, Vol. 7, No. 1, 2010, pp. 25-32. |
[2] | K. B. Jeong, S. G. Choi, “UV Immune System of Personalized Space” Facilities engineering paper collection, 2009. |
[3] | Photobiological Safety of Lamps and Lamp Devices, K62471-1, [IEC 62471, ed1, 2006-07] Safety Standards for Electrical Appliances, Enactment and Standards Agency Notification No. 2009-0476, 2009. |
[4] | Electrical Supplies Safety Standards K7000, "Individual Requirements for Safety, Electric Disinfectors, and Similar Electric Appliances for Household and Similar Electric Appliances" Revised Technical Standards Institute Notification 2008-907 December 12, 2008. |
[5] | J. Y. Park, M. K. Sung, J. W. Lee, “Numerical Analysis of Airborne Infection Control Performance of Germicidal Systems in a Temporary Shelter”, Journal of the Korea Institute of Healthcare Architecture, Vol. 21, No. 1, 2015, pp. 7-15. |
[6] | L. E. Murdoch, K. McKenzie, M. Maclean, S. J. Macgregor, J. G. Anderson, “Lethal effects of high-intensity violet 405nm light on Saccharomyces cerevisiae, Candida albicans, and on dormant and germinating spores of Aspergillus Niger’, Fungal biology, Vol. 117, No. 7-8, 2013, pp. 519-527. |
[7] | J. H. Kim, J. I. Bang, A. S. Choi, M. K. Sung, “An analysis on the Effect of Mold Sterilization in Apartment Using 405nm Visible Light LED”, Journal of Korea Institute of Architectural Sustainable Environment and Building Systems, 2019, pp. 580-598. |
[8] | H. M. Kang, G. H. Park, C. H. Cho, J. W. Park*, Y. S. Jung, Flow Analysis for Optimal Design of UVC-Air Pterilizer, KSMTE Annual Spring Conferences 2022. |
[9] | J. H. Lee, T. V. Dinh, H. N. Gil, B. K, Park, S. W. Lee, I. Y. Kim, I. Y. Choi, J. C. Kim, An Investigation of the Optimal Integrated Method using O3 and UVC-LED to Prevent Indoor Air Infection, KOSAE 64th Annual Conference 2021 Proceedings. |
[10] | Y. B. Jo, K. M. Kim, L. J. Min, C. H. Cho, J. W. Park, Y. S. Jung, Forward emission system air sterilizer using UVC-photocatalyst, KSMTE Annual Spring Conferences 2022. |
[11] | J. H. Kim, Y. L. Jo, J. I. Bang, A. S. Choi, M. K. Sung, “A study on the prediction of surface sterilization performance of ultraviolet germicidal irradiation system using radiance analysis”, Journal of Odor and indoor Environment, Vol. 18, No. 1, 2019, pp. 60-66. |
[12] | S. G. Choi, A study of air Sterilization System in Personalized Office Using Simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 6, 2010, pp. 353-360. |
[13] | UVC3535-25-100 semicon light co. ltd. FAB I49, Wongomae-ro 2beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do, Korea, https://www.semiconlight.com. |
[14] | KCL, Korea Conformity Laboratories, Korea Institute of Construction and Living Testing, Microbial Reduction Performance Test, Antibacterial /Antibacterial Fungal Test. 2020. |
[15] | Measurement method of harmful ultraviolet radiation KSA 5006 and calculation method of irradiation illumination of annexes. https://standard.go.kr/KSCI/search/portal/searchMain.do 2009. |
[16] | https://www.efsen.dk/uvc-for-disinfection-of-surfaces/?utm_source. 2020. |
APA Style
Ji-won Kim, Chang-shin Lee, Jeong-ja Bae. (2023). A Study on Eco-friendly Quarantine System Using Antiviral Surface Lighting. American Journal of Environmental Science and Engineering, 7(3), 61-66. https://doi.org/10.11648/j.ajese.20230703.12
ACS Style
Ji-won Kim; Chang-shin Lee; Jeong-ja Bae. A Study on Eco-friendly Quarantine System Using Antiviral Surface Lighting. Am. J. Environ. Sci. Eng. 2023, 7(3), 61-66. doi: 10.11648/j.ajese.20230703.12
AMA Style
Ji-won Kim, Chang-shin Lee, Jeong-ja Bae. A Study on Eco-friendly Quarantine System Using Antiviral Surface Lighting. Am J Environ Sci Eng. 2023;7(3):61-66. doi: 10.11648/j.ajese.20230703.12
@article{10.11648/j.ajese.20230703.12, author = {Ji-won Kim and Chang-shin Lee and Jeong-ja Bae}, title = {A Study on Eco-friendly Quarantine System Using Antiviral Surface Lighting}, journal = {American Journal of Environmental Science and Engineering}, volume = {7}, number = {3}, pages = {61-66}, doi = {10.11648/j.ajese.20230703.12}, url = {https://doi.org/10.11648/j.ajese.20230703.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajese.20230703.12}, abstract = {Due to the aftermath of COVID-19, we are using a continuous sterilization response system, such as sterilizing the interior of the building or using sterilized air in the air conditioning system. Chemical spraying is cumbersome and requires a lot of labor, and air conditioning systems have good air cleaning functions, but sterilization functions are difficult because they require sufficient residence time. Therefore, we developed an eco-friendly sterilization system that can disinfect the entire building with a single switch by adding a sterilization function to the existing lighting. It is a concept that sterilizes the space sufficiently by combining UVC-LED with high sterilization power with the existing LED surface lighting, using lighting during the day and sterilizing light inside the building without people at night. A PIR sensor was attached to each entrance or light to stop disinfection with a human body sensor in case people enter even at night. For the sterilization performance test, it was confirmed that 99.99% of 5 types of bacteria were sterilized as a result of testing the sterilization performance of attached bacteria at the maximum height of 1.5m or less of the certification body. The radiation intensity was simulated with a value similar to the dose irradiated in the experiment to have sterilizing power at the lighting height of 2.6m in an actual general office. As a result of calculating the sterilization time of the indoor space by coding the UVC-Led specification and the office space with MATLAB as input conditions, sterilization is possible if it is more than 4 hours. Through this study, an eco-friendly smart disinfection system was developed that disinfects the entire building with one switch when UVC is combined with general lighting and controlled from the central control room.}, year = {2023} }
TY - JOUR T1 - A Study on Eco-friendly Quarantine System Using Antiviral Surface Lighting AU - Ji-won Kim AU - Chang-shin Lee AU - Jeong-ja Bae Y1 - 2023/07/31 PY - 2023 N1 - https://doi.org/10.11648/j.ajese.20230703.12 DO - 10.11648/j.ajese.20230703.12 T2 - American Journal of Environmental Science and Engineering JF - American Journal of Environmental Science and Engineering JO - American Journal of Environmental Science and Engineering SP - 61 EP - 66 PB - Science Publishing Group SN - 2578-7993 UR - https://doi.org/10.11648/j.ajese.20230703.12 AB - Due to the aftermath of COVID-19, we are using a continuous sterilization response system, such as sterilizing the interior of the building or using sterilized air in the air conditioning system. Chemical spraying is cumbersome and requires a lot of labor, and air conditioning systems have good air cleaning functions, but sterilization functions are difficult because they require sufficient residence time. Therefore, we developed an eco-friendly sterilization system that can disinfect the entire building with a single switch by adding a sterilization function to the existing lighting. It is a concept that sterilizes the space sufficiently by combining UVC-LED with high sterilization power with the existing LED surface lighting, using lighting during the day and sterilizing light inside the building without people at night. A PIR sensor was attached to each entrance or light to stop disinfection with a human body sensor in case people enter even at night. For the sterilization performance test, it was confirmed that 99.99% of 5 types of bacteria were sterilized as a result of testing the sterilization performance of attached bacteria at the maximum height of 1.5m or less of the certification body. The radiation intensity was simulated with a value similar to the dose irradiated in the experiment to have sterilizing power at the lighting height of 2.6m in an actual general office. As a result of calculating the sterilization time of the indoor space by coding the UVC-Led specification and the office space with MATLAB as input conditions, sterilization is possible if it is more than 4 hours. Through this study, an eco-friendly smart disinfection system was developed that disinfects the entire building with one switch when UVC is combined with general lighting and controlled from the central control room. VL - 7 IS - 3 ER -