| Peer-Reviewed

Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery

Received: 30 April 2013     Published: 30 May 2013
Views:       Downloads:
Abstract

The various types of suture anchors have become widely accepted in the orthopaedic shoulder surgery. The common uses being for Bankarts repair and rotator cuff repair. The use of suture anchors in orthopaedic surgery for indications other than shoulder surgery is sparsely reported in the literature. We report on our observations from a single centre following use of anchors outside the shoulder joint. We have successfully used the suture anchors for repair of the lateral collateral ligament, the insertional tear of the Tendo-Achilles, fractures of the lower pole of the patella, triceps insertional tear, for repair of quadriceps tendon following partial avulsion. This highlights the importance of this tiny device in the armamentarium of a sports medicine surgeon.

Published in Advances in Surgical Sciences (Volume 1, Issue 1)
DOI 10.11648/j.ass.20130101.11
Page(s) 1-5
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2013. Published by Science Publishing Group

Previous article
Keywords

Suture Anchors, Shoulder Surgery, Fracture,MuscleTear, Tendo-Achilles Tear, Lateral Collateral ,Ligament, Bio-transfix, Bio-absorbable, Failure, Breakage

References
[1] Schroeder JA, Brown MK. Biocompatibility and degradation of collagen bone anchors in a rabbit model. J Biomed Mater Res 1999; 4 8: 309-314.
[2] Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W. Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws. Arthroscopy 2006; 22: 1204-1210.
[3] Driscoll P. Biopolymers in orthopaedics. Advanced Medical Technologies. Available from: http://mediligence.com/blog/ 2009/03/27/biopolymers-orthopedics.
[4] Bostman O, Hirvensalo E, Makinen J, Rokkanen P. Foreignbody reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 1990; 72: 592-596.
[5] Rokkanen PU, Bostman O, Hirvensalo E, et al. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 2000; 21: 2607-2613.
[6] Weiler A, Helling HJ, Kirch U, Zirbes TK, Rehm KE. Foreignbody reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep. J Bone Joint Surg Br 1996; 78: 369-376.
[7] Friden T, Rydholm U. Severe aseptic synovitis of the knee after biodegradable internal fixation. A case report. Acta Orthop Scand 1992; 63: 94-97.
[8] Ma CB, Francis K, Towers J, Irrgang J, Fu FH, Harner CH.Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and endobuttonpost fixation. Arthroscopy 2004; 20: 122-128.
[9] Busfield BT, Anderson LJ. Sterile pretibial abscess after anterior cruciate reconstruction from bioabsorbable interference screws: A report of 2 cases. Arthroscopy 2007; 23: 911.
[10] Martinek V, Friederich NF. Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 1999; 15: 317320.
[11] Warden WH, Chooljian D, Jackson DW. Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-L-lactic acid interference screws after anterior cruciate ligament reconstruction. Arthroscopy 2008; 24: 370.
[12] Baums MH, Zelle BA, Schultz W, Ernstberger T, Klinger HM. Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 2006; 14: 865-868.
[13] Bottoni CR, Deberardino TM, Fester EW, Mitchell D, Penrod BJ. An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 2000; 16: 395-398.
[14] Cossey AJ, Paterson RS. Loose intra-articular body following anterior cruciate ligament reconstruction. Arthroscopy 2005; 21:348-350.
[15] Werner A, Wild A, Ilg A, Krauspe R. Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 2002; 10: 30-32.
[16] Kwak JH, Sim JA, Kim SH, Lee KC, Lee BK. Delayed intra-articular inflammatory reaction due to poly-L-lactide bioabsorbable interference screw used in anterior cruciate ligament reconstruction. Arthroscopy 2008; 24: 243-246.
[17] Mastrokalos DS, Paessler HH. Allergic reaction to biodegradable interference poly-L-lactic acid screws after anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft. Arthroscopy 2008; 24: 732-733.
[18] Brantigan JW, McAfee PC, Cunningham BW, Wang H, Orbegoso CM. Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat. Spine (Phila Pa 1976) 1994; 19: 1436-1444.
[19] Brantigan JW, Steffee AD. A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine (Phila Pa 1976) 1993; 18: 2106-2107.
[20] Brantigan JW, Steffee AD, Lewis ML, Quinn LM, Persenaire JM. Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system: Two-year results from a Food and Drug Administration investigational device exemption clinical trial. Spine (Phila Pa 1976) 2000; 25: 1437-1446.
[21] Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic,and spinal implants. Biomaterials 2007; 28: 4845-4869.
[22] Toth JM, Wang M, Estes BT, Scifert JL, Seim HB III, Turner AS. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 2006; 27: 324-334.
[23] Briem D, Strametz S, Schroder K, et al. Response of primary fibroblasts and osteoblasts to plasma treated polyetheretherketone (PEEK) surfaces. J Mater Sci Mater Med 2005; 16: 671-677.
[24] Noiset O, Schneider YJ, Marchand-Brynaert J. Fibronectin adsorption or/and covalent grafting on chemically modified PEEK film surfaces. J Biomater Sci Polym Ed 1999; 10: 657-677.
[25] Ambard AJ, Mueninghoff L. Calcium phosphate cement: Review of mechanical and biological properties. J Prosthodont 2006; 15: 321-328.
[26] Ignjatovic N, Ajdukovic Z, Uskokovic D. New biocomposite [biphasic calcium phosphate/poly-DL-lactide-co-glycolide/biostimulative agent] filler for reconstruction of bone tissue changed by osteoporosis. J Mater Sci Mater Med 2005; 16: 621-626.
[27] Ruhe PQ, Hedberg EL, Padron NT, Spauwen PH, Jansen JA, Mikos AG. Biocompatibility and degradation of poly(DLlacticco-glycolic acid)/calcium phosphate cement composites. J Biomed Mater Res A 2005; 74: 533-544.
[28] Kokubo T, Kim HM, Kawashita M. Novel bioactive materials with different mechanical properties. Biomaterials 2003; 24: 2161-2175.
[29] Ozbaydar M, Elhassan B, Warner JJ. The use of anchors in shoulder surgery: A shift from metallic to bioabsorbable anchors. Arthroscopy 2007; 23: 1124-1126.
[30] Macarini L, Milillo P, Mocci A, Vinci R, Ettorre GC. Poly-L-lactic acid– hydroxyapatite (PLLA-HA) bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction surgery: MR evaluation of osteointegration and degradation features. Radiol Med 2008; 113: 1185-1197.
[31] Anand A,Kumar M,Kodikal G. Role of suture anchors in management of fractures of inferior pole of patella. Indian J Orthop. 2010 Jul; 44(3): 333-5.
Cite This Article
  • APA Style

    Ashish Anand, Raviraj A, Manish Kumar, Rajendran Ravindran. (2013). Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery. Advances in Surgical Sciences, 1(1), 1-5. https://doi.org/10.11648/j.ass.20130101.11

    Copy | Download

    ACS Style

    Ashish Anand; Raviraj A; Manish Kumar; Rajendran Ravindran. Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery. Adv. Surg. Sci. 2013, 1(1), 1-5. doi: 10.11648/j.ass.20130101.11

    Copy | Download

    AMA Style

    Ashish Anand, Raviraj A, Manish Kumar, Rajendran Ravindran. Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery. Adv Surg Sci. 2013;1(1):1-5. doi: 10.11648/j.ass.20130101.11

    Copy | Download

  • @article{10.11648/j.ass.20130101.11,
      author = {Ashish Anand and Raviraj A and Manish Kumar and Rajendran Ravindran},
      title = {Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery},
      journal = {Advances in Surgical Sciences},
      volume = {1},
      number = {1},
      pages = {1-5},
      doi = {10.11648/j.ass.20130101.11},
      url = {https://doi.org/10.11648/j.ass.20130101.11},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ass.20130101.11},
      abstract = {The various types of suture anchors have become widely accepted in the orthopaedic shoulder surgery. The common uses being for Bankarts repair and rotator cuff repair. The use of suture anchors in orthopaedic surgery for indications other than shoulder surgery is sparsely reported in the literature. We report on our observations from a single centre following use of anchors outside the shoulder joint. We have successfully used the suture anchors for repair of the lateral collateral ligament, the insertional tear of the Tendo-Achilles, fractures of the lower pole of the patella, triceps insertional tear, for repair of quadriceps tendon following partial avulsion. This highlights the importance of this tiny device in the armamentarium of a sports medicine surgeon.},
     year = {2013}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Suture Anchors in Orthopaedics – Uses other than Shoulder Surgery
    AU  - Ashish Anand
    AU  - Raviraj A
    AU  - Manish Kumar
    AU  - Rajendran Ravindran
    Y1  - 2013/05/30
    PY  - 2013
    N1  - https://doi.org/10.11648/j.ass.20130101.11
    DO  - 10.11648/j.ass.20130101.11
    T2  - Advances in Surgical Sciences
    JF  - Advances in Surgical Sciences
    JO  - Advances in Surgical Sciences
    SP  - 1
    EP  - 5
    PB  - Science Publishing Group
    SN  - 2376-6182
    UR  - https://doi.org/10.11648/j.ass.20130101.11
    AB  - The various types of suture anchors have become widely accepted in the orthopaedic shoulder surgery. The common uses being for Bankarts repair and rotator cuff repair. The use of suture anchors in orthopaedic surgery for indications other than shoulder surgery is sparsely reported in the literature. We report on our observations from a single centre following use of anchors outside the shoulder joint. We have successfully used the suture anchors for repair of the lateral collateral ligament, the insertional tear of the Tendo-Achilles, fractures of the lower pole of the patella, triceps insertional tear, for repair of quadriceps tendon following partial avulsion. This highlights the importance of this tiny device in the armamentarium of a sports medicine surgeon.
    VL  - 1
    IS  - 1
    ER  - 

    Copy | Download

Author Information
  • Fortis Hospitals, Bangalore, India

  • Fortis Hospitals, Bangalore, India

  • Fortis Hospitals, Bangalore, India

  • Fortis Hospitals, Bangalore, India

  • Sections